ニュース高温実験炉 夏季と冬季の安全上の注意

高温実験炉 夏季と冬季の安全上の注意

2025-12-08

共有:

High-temperature laboratory furnaces are essential tools in materials science, chemistry, metallurgy, and quality testing. But while the furnace’s internal temperature can reach 1000–1800°C, its operation is strongly affected by seasonal environmental conditions. Summer and winter present very different challenges related to heat, humidity, power stability, and sample behavior.

This article provides a clear comparison of how to safely operate laboratory furnaces across seasons and what precautions technicians, researchers, and industrial operators should follow.

Why Seasonal Differences Matter

Ambient temperature, humidity, and airflow directly influence:

  • Furnace heating efficiency
  • Cooling time
  • Electronic control performance
  • Safety risks such as corrosion, overheating, electrical faults, and thermal shock

Understanding these variations helps ensure stable operation, prolonged equipment life, and operator safety.

Summer Precautions: Managing Heat & Moisture

Preventing Furnace Overheating

Summer temperatures raise the baseline temperature of the laboratory. Because most high-temperature furnaces rely on natural convection around the housing:

  • Internal electronics can overheat more easily
  • Cooling fans must work harder
  • Thermal sensors may drift if airflow is insufficient

Best Practices for Summer:

  • Maintain lab temperature at 18–28°C using air conditioning.
  • Ensure 30–50 cm clearance around the furnace for airflow.
  • Avoid placing the furnace in direct sunlight or near other heat sources.
  • Schedule long-duration or high-temperature runs during cooler hours when possible.

Controlling Humidity

High humidity is one of summer’s biggest risks. It can lead to:

  • Moisture absorption in ceramic insulation
  • Corrosion of electrical terminals
  • Condensation inside control boxes
  • Increased likelihood of electrical short circuits

How to Reduce Moisture Risks:

  • Keep a dehumidifier running in the room.
  • Store crucibles, refractories, and powders in sealed containers.
  • Preheat the empty furnace to 120–150°C briefly to remove moisture before high-temperature operation.

Electrical Stability in Summer

Air-conditioners and other large equipment may cause:

  • Voltage fluctuations
  • Power drops
  • Controller errors or furnace shutoff during heating cycles

Suggested Measures:

  • Use a voltage stabilizer or UPS specifically rated for furnaces.
  • Avoid sharing the power line with refrigerators, AC units, and pumps.

Summer Sample Handling

Materials often absorb moisture during humid months. Loading wet or damp samples can cause:

  • Cracking
  • Spalling of crucibles
  • Steam explosions inside the furnace

Always dry samples before loading, especially ceramics, minerals, and biological ashes.

Winter Precautions: Reduce Thermal Shock & Manage Dry Conditions

Avoiding Thermal Shock

Laboratory temperatures may drop significantly overnight. If the furnace door is opened while hot into cold room air:

  • Heating elements experience thermal stress
  • Refractory linings crack
  • Quartz tubes may shatter

Winter Rules for Thermal Shock Prevention:

  • Avoid rapid opening of the furnace above 300–400°C.
  • Use controlled or partial door opening to release heat gradually.
  • Warm the room slightly before starting daily operations.

Low Humidity & Static Electricity

Cold and dry winter air increases static buildup, which can harm:

  • PIDコントローラ
  • Touch screens
  • Data communication boards

Solutions:

  • Use electrostatic mats or grounding straps.
  • Maintain relative humidity at 30–50%.

Cold Start Precautions

If electronics or insulation begin at a very low temperature:

  • Sensors may drift
  • Heating elements undergo stress
  • Furnace may heat unevenly

Best Practices:

  • Allow the furnace to sit at room temperature for 30–60 minutes before powering on.
  • Run a low-temperature warm-up cycle (e.g., 50–100°C for 20 minutes).

Winter Sample Handling

In winter, samples and crucibles can become brittle or accumulate frost condensation if brought from outdoors.

Before loading:

  • Warm samples naturally to room temperature.
  • Avoid placing cold materials into a hot furnace to prevent cracking.

結論

Seasonal environmental changes significantly impact the safe and effective operation of high-temperature laboratory furnaces.

  • Summer focuses on managing heat, humidity, and power stability.
  • Winter focuses on preventing thermal shock, managing static, and avoiding cold-start damage.

By applying targeted safety practices, laboratories can extend furnace lifespan, reduce operational risks, and ensure consistent temperature performance year-round.